Error
code
Description
Action
166-201-000
ISMP
indicates
I2C
errors
on
bus
X.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
166-201-001
ISMP
indicates
I2C
errors
on
bus
P.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Power
backplane
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Power
backplane
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
166-201-002
ISMP
indicates
I2C
errors
on
bus
I.
Reseat
the
I/O
board.
Replace
the
I/O
board.
166-201-003
ISMP
indicates
I2C
errors
on
bus
C.
1.
Reseat
the
following
components:
a.
Microprocessor
tray
b.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
tray
b.
I/O
board
166-201-004
ISMP
indicates
I2C
errors
on
bus
M.
1.
Reseat
the
following
components:
a.
I/O
board
b.
Memory
card
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
I/O
board
b.
Memory
card
c.
(Trained
service
technician
only)
Microprocessor
tray
Chapter
2.
Diagnostics
71