System-error
log
message
Action
Hurricane
SMI
1.2V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hurricane
Vtt
MR
1.5V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hvtt
IB
1.8V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hvtr
IB
2.5V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
I/O
Card
Power
Good
Fault
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine,
if
one
is
present.
2.
Reseat
the
I/O
board.
3.
Replace
the
I/O
board.
4.
(Trained
service
technician
only)
Replace
the
PCI-X
board.
IB
MR
Reg
1.8V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Invalid
CPU
configuration
Make
sure
that
the
microprocessors
have
been
installed
in
the
correct
order
(see
Invalid
Fan
configuration
Replace
any
missing
or
failed
fans.
IP
address
of
default
gateway
modified
from
x.x.x.x
Information
only
IP
address
of
network
interface
modified
from
x.x.x.x
Information
only
IP
subnet
mask
of
network
interface
modified
from
x.x.x.x
Information
only
Chapter
2.
Diagnostics
85