v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
035-277-001
Adapter
Local
RAM
test
error.
1.
Update
the
RAID
controller
firmware
(see
2.
Reseat
the
RAID
controller.
3.
Replace
the
RAID
controller.
035-278-001
Adapter
NVSRAM
test
error.
1.
Update
the
RAID
controller
firmware
(see
2.
Reseat
the
RAID
controller.
3.
Replace
the
RAID
controller.
035-279-001
Adapter
Cache
test
error.
1.
Update
the
RAID
controller
firmware
(see
2.
Reseat
the
RAID
controller.
3.
Replace
the
RAID
controller.
035-280-001
Adapter
Drive
test
error.
Replace
the
attached
drive.
035-281-001
Adapter
Drive
error.
Replace
the
attached
drive.
035-282-001
Adapter
Parameters
set
error.
1.
Update
the
RAID
controller
firmware
(see
2.
Reseat
the
RAID
controller.
3.
Replace
the
RAID
controller.
035-283-001
Adapter
Battery
error.
Replace
the
battery
module
on
the
RAID
controller.
035-xxx-cnn
c
=
ServeRAID
channel
number,
nn
=
SCSI
ID
of
failing
fixed
disk
drive.
1.
Check
the
BMC
log
or
system-error
log
before
replacing
a
FRU.
2.
Reseat
the
hard
disk
drive
on
channel
C,
SCSI
ID
nn.
3.
Replace
the
hard
disk
drive
on
channel
C,
SCSI
ID
nn.
035-xxx-snn
nn
=
SCSI
ID
of
failing
fixed
disk.
1.
Check
the
BMC
log
or
system-error
log
before
replacing
a
FRU.
2.
Reseat
the
SCSI
disk
with
ID
nn.
3.
Replace
the
SCSI
disk
with
ID
nn.
075-xxx-000
Failed
power
supply
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
backplane
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
68
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide