v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
SMI
reported
a
Machine
Check
on
Memory
Card
%d,
Dimm
%d
Note:
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
1.
Reseat
the
DIMM.
2.
Reseat
the
memory
card.
3.
Replace
the
DIMM.
Software
NMI
Make
sure
that
the
system
software
is
operating
correctly
and
does
not
conflict
with
other
software;
the
system
software
has
created
a
software
NMI.
System
Approaching
Maximum
Power
Consumption
1.
Install
another
power
supply
(if
possible)
and
make
sure
that
the
ac
power
cords
are
correctly
connected.
2.
Remove
devices
that
consume
an
extraordinary
amount
of
power.
3.
Replace
the
power
backplane.
System
Boot
Failed
1.
Check
the
POST/BIOS
boot
checkpoint
indicator
and
see
the
applicable
documentation.
2.
Make
sure
that
the
memory
card
and
DIMMs
are
correctly
connected
and
seated
and
that
they
are
functional.
3.
Attempt
to
start
the
server
from
the
backup
BIOS
page.
System
Complex
Powered
Down
Information
only
System
Complex
Powered
Up
Information
only
System-error
log
full
Clear
the
event
log.
System
log
75%%
full
Information
only
System
Memory
Error
1.
Reseat
the
memory
adapter
and
DIMMs.
2.
Replace
the
memory.
System
Running
Nonredundant
Power
1.
Install
another
power
supply
(if
possible)
and
make
sure
that
the
ac
power
cords
are
correctly
connected.
2.
Remove
devices
that
consume
an
extraordinary
amount
of
power.
3.
Replace
the
power
backplane.
User
<USERID>
attempting
to
power/reset
server
Information
only
Video
1.8V
Power
Good
Fault
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
Video
2.5V
Power
Good
Fault
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine,
if
one
is
present.
2.
Reseat
the
I/O
board.
3.
Replace
the
I/O
board.
Video
Core
1.8V
Power
Good
Fault
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
Chapter
2.
Diagnostics
91