v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
Three
short
beeps
Memory
error.
Note:
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
1.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
DIMM
b.
Memory
card
c.
(Trained
service
technician
only)
Microprocessor
tray
One
continuous
beep
Microprocessor
error.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
Optional
microprocessor
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
Optional
microprocessor
c.
(Trained
service
technician
only)
Microprocessor
tray
Repeating
short
beeps
Keyboard
error.
1.
Reseat
the
following
components:
a.
Keyboard
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Repeating
long
beeps
Memory
error.
Reseat
the
DIMMs.
Chapter
2.
Diagnostics
17