v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
00180100
A
PCI
adapter
has
requested
memory
resources
that
are
not
available.
1.
Change
the
order
of
the
adapters
in
the
PCI-X
slots.
Make
sure
that
the
boot
device
is
positioned
early
in
the
scan
order
(see
the
User’s
Guide
for
information
about
the
scan
order).
2.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
If
the
memory
resource
settings
are
not
correct,
change
them.
3.
If
all
memory
resources
are
being
used,
remove
an
adapter
to
make
memory
available
to
the
adapter.
Disabling
the
BIOS
on
the
adapter
should
correct
the
error.
See
the
documentation
that
comes
with
the
adapter.
00180200
No
more
I/O
space
is
available
for
a
PCI
adapter.
1.
If
the
error
code
indicates
a
particular
PCI
or
PCI-X
slot
or
device,
remove
that
device.
2.
If
the
error
continues,
reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI-X
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180300
No
more
memory
(above
1
MB
for
a
PCI
adapter).
1.
If
the
error
code
indicates
a
particular
PCI
or
PCI-X
slot
or
device,
remove
that
device.
2.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI-X
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180400
No
more
memory
(below
1
MB
for
a
PCI
adapter).
1.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI-X
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180500
PCI
option
ROM
checksum
error.
1.
Remove
the
failing
adapter.
2.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI-X
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
30
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide