Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
Diagnostics panel LED
FRU/action
TEMPERATURE LED on
1.
Ambient temperature must be within normal operating specifications.
See “Features and specifications” on page 3.
2. Ensure fans are operating correctly.
3. Ensure both air baffles are installed.
4. Examine System Error Log.
a. System over recommended temperature
v
Information LED panel
b. DASD over recommended temperature (DASD LED also on)
1) Overheating hard drive
2) DASD backplane
c. System over recommended temperature for CPU
x
(where
x
is 1 or 2)
(CPU LED is also on)
1) CPU
x
2) System board
5. If the CPU LED on the diagnostics panel is also lit, one of the
microprocessors has caused the error.
CPU/VRM MISMATCH LED on
1.
Move the microprocessor in socket 1 to socket 2, and move the
microprocessor in socket 2 to socket 1.
2. Ensure that both microprocessors are of the same type, with the same core
frequency and the same L2 size.
3. Ensure that both VRMs are of the same type.
4. Ensure that both VRMs are supported in your server model.
5. If a microprocessor is missing from socket 1, install a microprocessor in
socket 1.
FAN LED on
1.
Check individual fan LEDs.
2. Replace respective fan.
3. Fan cable.
4. System board.
5. Power cage assembly.
Diagnostic error codes
Note:
In the following error codes, if
XXX
is
000
,
195
, or
197
,
do not
replace a
FRU. The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to stop the test.
197
Warning; a hardware failure might not have occurred.
For all error codes, replace the FRU or take the action indicated.
Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
001-XXX-000
(Failed core tests)
v
System board
88
xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer xSeries 345 Type 8670
Page 1: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 18: ...8 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 88: ...78 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 124: ...114 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 130: ...120 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 141: ...Chapter 8 Related service information 131...
Page 142: ...132 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 143: ...Chapter 8 Related service information 133...
Page 144: ...134 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 145: ...Chapter 8 Related service information 135...
Page 146: ...136 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 147: ...Chapter 8 Related service information 137...
Page 157: ...Chapter 8 Related service information 147...
Page 158: ...148 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 159: ...Chapter 8 Related service information 149...
Page 160: ...150 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 161: ...Chapter 8 Related service information 151...
Page 162: ...152 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 166: ...156 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 174: ...164 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ......
Page 176: ...Part Number 48P9718 1P P N 48P9718...