Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
AC good LED
DC good LED
Description
FRU/action
On
Off
Standby mode or dc
problem.
1.
Check system board cable connectors
J4 and J10.
Move switch 3 of SW 1 to
bypass power control. If the dc good LED
is lit, press Ctrl+Alt+Delete. Watch the
screen for any POST errors. Check the
System Error Log for any listed problems. If
the system starts with no errors:
a. Power switch assembly
b. System board
2. Remove the adapters and disconnect the
cables and power connectors to all internal
and external devices. Turn on the system.
If the dc good LED is lit, replace the
adapters and devices one at a time until
you isolate the problem.
3. Power supply.
4. Power cage assembly.
5. System board.
On
On
Power is working properly.
N/A
POST error codes
In the following error codes,
X
can be any number or letter.
Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
062
(Three consecutive startup failures using
the default configuration.)
1.
Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
4. Microprocessor.
101, 102
(System and processor error)
v
System board
106
(System and processor error)
v
System board
111
(Channel check error)
1.
Memory DIMM
2. System board
114
(Adapter read-only memory error)
1.
Failing adapter.
2. Run diagnostics.
129
(Internal cache error)
1.
Microprocessor
2. Optional microprocessor (if installed)
151
(Real time clock error)
1.
Run diagnostics.
2. Battery.
3. System board.
161
(Real time clock battery error)
1.
Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
Chapter 6. Symptom-to-FRU index
101
Summary of Contents for eServer xSeries 345 Type 8670
Page 1: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 18: ...8 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 88: ...78 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 124: ...114 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 130: ...120 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 141: ...Chapter 8 Related service information 131...
Page 142: ...132 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 143: ...Chapter 8 Related service information 133...
Page 144: ...134 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 145: ...Chapter 8 Related service information 135...
Page 146: ...136 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 147: ...Chapter 8 Related service information 137...
Page 157: ...Chapter 8 Related service information 147...
Page 158: ...148 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 159: ...Chapter 8 Related service information 149...
Page 160: ...150 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 161: ...Chapter 8 Related service information 151...
Page 162: ...152 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 166: ...156 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 174: ...164 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ......
Page 176: ...Part Number 48P9718 1P P N 48P9718...