Unable to communicate with the following devices.
(Channel :
SID)
Explanation: Devices at the channel and SCSI ID specified in the
message are not responding. The devices may have been
removed.
Action: Check that the device(s) are at the location specified. If
they are located in an external enclosure, make sure that the
external enclosure is powered on.
Download codeblk (via bootblk) is ready.
Explanation: Preparations for the download of the firmware to the
controller are complete.
Action: Insert the BIOS/Firmware Diskette and download the
firmware. Restart the system.
Controller is not responding properly - Run Diagnostics.
Explanation: The controller is not responding appropriately to
commands.
Action: Use the ServeRAID DOS Configuration Utility and run the
diagnostics.
System PCI BIOS does not respond to commands; no logical
drives are installed.
Explanation: The system's PCI BIOS is returning error status in
response to calls to it.
Action: Refer to the system's HMM and run diagnostics.