a. Carefully grasp the adapter
.3/
by its top edge
or upper corners, and align it with the expansion
slot on the system board.
b. Press the adapter
firmly into the expansion slot.
Attention
When you install an adapter in the server, be
sure that it is completely and correctly seated in
the system board connector before you apply
power. Incomplete insertion might cause
damage to the system board or the adapter.
9. If you are installing an adapter in PCI slots 1, 2, 3, or
4:
a. Refer to the illustration in “Hot-plug PCI adapter
installation” on page 165 for operation of the
adapter retention latch on the end of the slot
near the rear of the server.
b. Lower the tab on the adapter guide over the tab
on the top corner of the adapter. Rotate the
adapter retention latch clockwise until it snaps
into place.
If you are installing an adapter in PCI slot 5 or in the
ISA slot:
a. Align the rounded notch in the retaining bracket
on the adapter
.5/
with the threaded hole in the
expansion-slot frame. The retaining bracket on
the adapter fits into the space that was occupied
by the expansion-slot cover.
b. Insert the expansion-slot screw
.3/
that you
removed earlier into the threaded hole, and push
the rounded notch up against the screw.
c. Tighten the expansion-slot screw firmly.
Note
The expansion slot also has an adapter
retention latch
.4/
at the end of the slot
toward the middle of the server. To remove
the adapter, you need to push this adapter
retention latch
.4/
away from the adapter
until the top edge of the adapter is past the
latch.
10. Connect any needed cables to the adapter.
11. If you have other options to install or remove, do so
now; otherwise, go to “Completing the installation” on
page 178.
Verifying compatibility between network
adapters and device drivers:
The server supports several types of network adapters. If
you are having trouble with the installation or operation of
a network adapter or network operating system, ensure
Netfinity 5500 M20 - Type 8662
171
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...