GETSTATUS command to obtain progress
information about the rebuild.
Supported operating systems: Windows NT,
OS/2, NetWare, OpenServer, UnixWare, and
DOS
Command:
IPSSEND REBUILD
Controller DCh DSID NCh
NSID
Replace:
Controller with the ServeRAID controller
number (1 to 8)
DCh with the channel number for the
Defunct drive (1 to 3)
DSID with the SCSI ID for the Defunct
Drive
(0 to 15)
NCh with the channel number for the
New Drive (1 to 3)
NSID with the SCSI ID for the New
Drive
(0 to 15)
SETSTATE Use the SETSTATE command to change the
state of a physical device from its current
state to a new state.
Attention
You must be very careful when you use
this command. For example, you might
lose data if you reset a Defunct (DDD)
device to Online (ONL) without first
performing a Rebuild operation.
Supported operating systems: Windows NT,
OS/2, NetWare, OpenServer, UnixWare, and
DOS
Command:
IPSSEND SETSTATE
Controller Channel SID
NState
Replace:
Controller with the ServeRAID controller
number (1 to 8)
Channel with the channel number for the
drive (1 to 3)
SID with the SCSI ID for the drive (0 to
15)
NState with the new state for the drive.
Valid states are: EMP for Empty, RDY
for Ready, HSP for Hot Spare, SHS for
Standby Hot Spare, DDD for Defunct
Disk Drive, DHS for Defunct Hot Spare,
RBL for Rebuild, SBY for Standby, and
ONL for Online. (See “Setting physical
Netfinity 5500 M20 - Type 8662
123
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...