in the system are attached to a single disk-storage adapter
or controller (such as the ServeRAID adapter or controller),
you can skip the instructions in this section and go directly
to “Installing the files while installing UnixWare” on
page 150 or “Installing the files after installing UnixWare”
on page 151.
If you are attaching devices to multiple disk-storage
adapters or controllers (including IDE and SCSI controllers
integrated on the system board), use the following
instructions.
If you are installing UnixWare on a drive attached to a
ServeRAID adapter or controller, follow the
instructions in “Installing UnixWare on a ServeRAID
drive.”
If you are installing UnixWare on a drive attached to a
non-ServeRAID adapter or controller and you intend
to store only data on the drives attached to the
ServeRAID adapters and controllers, follow the
instructions in “Installing UnixWare on a
non-ServeRAID drive” on page 149.
Installing UnixWare on a ServeRAID drive:
Use
the following instructions if you are using multiple
disk-storage adapters or controllers and you are installing
UnixWare on a drive attached to a ServeRAID adapter or
controller.
Note
If you are not using multiple disk-storage adapters and
controllers, go to “Installing the files while installing
UnixWare” on page 150.
1. Install all ServeRAID adapters that you intend to use
in the system.
2. Using the ServeRAID Configuration Program, create
all of the arrays and define all of the logical drives.
3. Make a list of all of the ServeRAID adapters and
controllers, including the order and slot number,
installed in the system. To do this:
a. Turn on the server.
b. When the ServeRAID Mini-Configuration prompt
appears, press Ctrl+i. When a system contains
more than one ServeRAID adapter or controller,
a selection screen appears.
c. The menu lists the ServeRAID adapters and
controllers in order. Select the first ServeRAID
adapter or controller from the menu.
d. Select Advanced Functions from the Main
Menu.
e. Select View Controller and PCI Information
from the Advanced Functions menu.
Netfinity 5500 M20 - Type 8662
147
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...