Installing ServerRAID device drivers for
OS/2:
This section provides two sets of instructions for installing
the ServeRAID device driver: one that you can use during
the initial OS/2 installation and one that you can use if
OS/2 already is installed.
The ServeRAID Administration and Monitoring Program
files and background-server component for OS/2 install
automatically when you use the instructions in this chapter
to install the ServeRAID device driver for OS/2.
Installing the files while installing OS/2:
You can
use the following instructions to install the ServeRAID
device driver and Administration and Monitoring Program
files while installing OS/2 Warp Server.
Note
If you install these files on a logical drive that has its
write policy set to the write-back mode, wait at least
10 seconds after being prompted to press
Ctrl
+
Alt
+
Del before you actually press the keys.
Waiting 10 seconds or longer gives the ServeRAID
adapter or controller the time needed to flush all
dirty-cache pages out to the hard disk.
To install the ServeRAID files while installing OS/2:
1. Use the ServerGuide Diskette Factory to create an
IBM ServeRAID Device Driver Diskette.
2. Make a copy of the
OS/2 Warp Diskette 1 and label it
Copy of OS/2 Diskette 1.
3. Copy the IPSRAID.ADD file from the OS2 directory
on the
IBM ServeRAID Device Driver Diskette to the
Copy of OS/2 Diskette 1.
If there is not enough space, delete files not needed
in the installation (such as proprietary CD-ROM or
SCSI device drivers). Make sure you remove all
entries referring to any device drivers you delete from
the CONFIG.SYS file.
4. Edit the CONFIG.SYS file on the
Copy of OS/2
Diskette 1 to add the following lines:
BASEDEV=IPSRAID.ADD
SET COPYFROMFLOPPY=1
5. Install OS/2, but when prompted to insert diskette 1,
use the updated
Copy of OS/2 Diskette 1.
6. After you complete the OS/2 installation, insert the
IBM ServeRAID Device Driver Diskette.
7. From an OS/2 window, type:
a:
140
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...