Error Code/Symptom
FRU/Action
089-XXX-001
(Failed Microprocessor test)
1. VRM 1 or VRM 2
2. Microprocessor CPU 1
089-XXX-002
(Failed Microprocessor test)
1. VRM 3 or VRM 2
2. Microprocessor CPU 2
089-XXX-003
(Failed Microprocessor test)
1. VRM 4 or VRM 5
2. Microprocessor CPU 3
089-XXX-004
(Failed Microprocessor test)
1. VRM 6 or VRM 5
2. Microprocessor CPU 4
165-XXX-000
(Failed System Board test)
1. System Board Before
replacing the system
board, ensure that
system board jumper
J51 is not installed (the
default) when the error
occurs.
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive
Backplane
180-XXX-000
(Diagnostics LED failure)
1. Run Diagnostic LED
test for the failing
LED
180-XXX-001
(Failed information LED
panel test)
1. Information LED
Panel
2. Power Switch
Assembly
180-XXX-002
(Failed Diagnostics LED
Panel test)
1. Diagnostics LED
Panel
2. Power Switch
Assembly
180-XXX-003
(Failed System Board LED
test)
1. Run hot-swap PCI
latch test in Other
Devices under
Extended Tests
2. System Board
180-XXX-004
(Failed Processor Board
LED test)
1. Processor Board
2. System Board
180-XXX-005
(Failed SCSI Backplane
LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
201-XXX-001
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J1
201-XXX-002
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J2
201-XXX-003
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J3
296
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...