The background-server components for Windows NT 3.5X
and Windows NT 4.0 install automatically when you use
the instructions in this chapter to install the ServeRAID
device drivers.
Installing the files while installing Windows NT:
To install the ServeRAID files while installing Windows NT:
1. Use the ServerGuide Diskette Factory to create an
IBM ServeRAID Device Driver Diskette.
2. Insert the Windows NT boot diskette into the diskette
drive or insert the bootable Windows NT CD into the
CD-ROM drive; then, restart the server.
3. When the message
Setup is inspecting the
computer's hardware configuration...
appears,
press the F6 key.
4. After loading some files, Windows NT displays a
screen that allows you to manually specify an
adapter. When this screen appears, press S to
specify additional devices.
5. When prompted in the next window, select Other
from the list.
6. When prompted to insert the
Manufacturer-supplied-hardware support disk
,
insert the
IBM ServeRAID Device Driver Diskette into
the diskette drive; then, press Enter.
7. Select IBM ServeRAID Adapter; then, press Enter.
A message similar to the following will appear.
Setup
is loading files (IBM ServeRAID Adapter)...
.
8. When prompted, press Enter to continue.
9. Use the instructions provided in the Windows NT
manual to complete the normal installation process.
10. After you complete the installation, be sure to apply
the latest Service Pack.
Installing the files after installing Windows NT:
To install the ServeRAID files after Installing Windows NT:
1. Use the ServerGuide Diskette Factory to create an
IBM ServeRAID Device Driver Diskette.
2. Insert the
IBM ServeRAID Device Driver Diskette into
the diskette drive.
3. From the Windows NT Start Menu, select Settings;
then, select Control Panel.
4. Select SCSI Adapter; then, select the Drivers tab.
5. Select Add; then, select Have Disk.
6. In the Copy manufacturer's files from field, type:
a:\nt
7. Select OK; then in the next dialog box, select OK
again.
8. When a message appears asking if you want to use
the currently installed device driver or if you want to
install a new one, select New.
9. When prompted to enter the full path to the IBM
ServeRAID files, type:
Netfinity 5500 M20 - Type 8662
135
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...