6. Select the adapter pair you want and then select OK.
Note that the integrated Ethernet controller is located
at PCI primary bus 0, slot 14.
7. Select Close to exit from the Network setup.
When you restart the server, the failover function will
be in effect.
If a failover occurs, a message is written to the Windows
NT Event Viewer log. If the DMI instrumentation code for
the integrated Ethernet controller is active (PCNET.EXE
was run), a pop-up message is generated also.
IntraNetWare
1. Add the redundant NIC adapter according to the
instructions provided with the adapter and in
“Adapters” on page 161.
2. Load the device driver by using the following
command:
LOAD
d
:\
path
\PCNTNW.LAN PRIMARY=
x
SECONDARY=
y
where
d and path are the drive and path where the
driver is located, and
x and y are the PCI slot
numbers where the redundant pair is located.
The slot number associated with the integrated
Ethernet controller can vary depending upon the
configuration of the server. To determine the slot
number, load the driver with no parameters. The
driver will display the available slot numbers. The slot
number that is greater than 10000 will be the slot
number of integrated Ethernet controller. When the
slot number of the integrated Ethernet controller is
determined, reload the driver with the appropriate
parameters.
3. When the driver is loaded, bind it to a protocol stack.
The failover function is now enabled. If a failover occurs:
A message is generated to the operating system
console.
The custom counters for the device driver contains
variables that define the state of the failover function
and the location of the redundant pair. You can use
the NetWare Monitor to view the custom counters.
42
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...