7. Tighten all screws to secure both slide-bracket
assemblies. If you are using a torque screwdriver,
use the following torque setting: 8–11 Nm (70.8–97.0
in/lbs).
8. Attach the cable-management arm to the rear of the
rack:
a. Position the cable-management arm bracket on
the outside of the mounting rail.
b. Insert screws (M6 by 16 mm) through the
cable-management arm bracket, mounting rail,
and cage nuts. Tighten the screws.
c. Position the server bracket on the
cable-management arm.
d. Insert screws through the cable-management
arm and the server bracket. Attach M6 hex nuts
to the screws and tighten the hex nuts.