To add a power supply:
Caution
Never remove the cover on a power supply or any
part that has the following label attached.
Hazardous voltage, current, and energy levels are
present inside any component that has this label
attached. There are no serviceable parts inside these
components.
1
2
1. Remove the filler panel
.2/
:
a. Remove the four screws
.1/
from the filler panel.
b. Remove the filler panel
.2/
from the
power-supply bay and save it and the four
screws you removed.
Note
During normal operation, each power-supply
bay must have either a power supply or filler
panel installed for proper cooling.
2. Place the handle
.6/
on the power supply in the open
position, and slide the power supply into the chassis.
3. Gently close the handle
.6/
on the power supply to
seat the power supply in the bay.
4. Plug the power cord for the added power supply into
power cord connector
.8/
.
198