5-39
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
866
2
(When mounting the AAVM)
60 seconds continuous, AAVM communication Data Error
●
(Results / Symptoms)
1. Control Function – AAVM operation failure
(Checking list)
1. CN-401 (#86) – CN-51 (#22) Checking Open/Short
2. CN-401 (#87) – CN-51 (#32) Checking Open/Short
867
2
60 seconds continuous, RDU communication Data Error
●
(Results / Symptoms)
1. Control Function – RDU operation failure
(Checking list)
1. CN-376 (#10) – CN-51 (#22) Checking Open/Short
2. CN-376 (#18) – CN-51 (#32) Checking Open/Short
868
2
60 seconds continuous, Switch Controller communication Data Error
●
(Results / Symptoms)
1. Control Function – Switch Controller operation failure
(Checking list)
1. CN-56A (#7) – CN-51 (#22) Checking Open/Short
2. CN-56A (#6) – CN-51 (#32) Checking Open/Short
869
2
(When mounting the BKCU)
60 seconds continuous, BKCU communication Data Error
●
(Results / Symptoms)
1. Control Function – BKCU operation failure
(Checking list)
1. CS-2B (#A) – CN-51 (#22) Checking Open/Short
2. CS-2B (#B) – CN-51 (#32) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
※
Some error codes are not applied to this machine.