6-60
TEST PROCEDURE
Test 15 : Check voltage at CN-52 (14)
and ground.
Prepare 1 piece of thin sharp pin, steel or
copper.
Insert prepared pin to rear side of
connectors : One pin to (14) of CN-52.
Starting switch ON.
Check voltage as figure.
MCU
CN-51
CN-52
Female
CN-52
1
2
3
4
5
6
7
8
9
10
31
32
33
34
36
37
38
39
40
11
21
20
30
Multimeter
GROUND
PIN
14
(1)
①
②
③
④
2)
SPEC : Actuator operating : 1~5 V
300L6MS18