6-32
9. WHEN FUEL GAUGE DOES NOT OPERATE (HCESPN 301, FMI 3 or 4)
·
Before disconnecting the connector, always turn the starting switch OFF.
·
Before carrying out below procedure, check all the related connectors are properly inserted.
·
After checking, insert the disconnected connectors again immediately unless otherwise specified.
CN-51
MCU
5
CN-52
26
CD-2
2
1
FUEL LEVEL SENDER
Cause
Remedy
Defective MCU or
cluster
Disconnection in
wiring harness or
poor contact
between fuel
sender-MCU
Defective fuel
sender
Replace
Repair or replace
Replace
YES
YES
Starting switch : OFF
Spec : 50~600
Ω
See table
Check resistance
between fuel
sender (1) and
(2)
Check resistance
between CN-51
(5) and CN-52
(26)
Starting switch : OFF
Disconnect CN-51, CN-52
Spec : 50~600
Ω
NO
NO
300L6ES10
Check Table
Range
Resistance (
Ω
)
Range
Resistance (
Ω
)
Full
50
5/12
400
11/12
100
4/12
450
10/12
150
3/12
500
9/12
200
2/12
550
8/12
250
1/12
600
7/12
300
Empty warning
700
6/12
350
-
-