5-8
GROUP 5 TRAVEL SPEED CONTROL SYSTEM
Main pump Pilot pump
Engine
MCU
Travel speed
solenoid valve
Regulator
Travel motor
Travel speed switch signal
Travel speed
pilot lamp
Drive signal
Cluster
CAN #2
Main control valve
Option
Arm 1
Boom 2
Swing
Bucket
Arm 2
Arm regen
Boom 1
Option
Travel(RH)
Travel(LH)
(Dozer)
Travel speed can be switched manually by pressing the travel speed switch on the cluster.
Default : Turtle (Low speed)
※
130ZF5MS07
Speed
Travel speed
solenoid valve
Lamp
on cluster
Operation
Low
OFF
Turtle
Low speed, high driving torque in the travel motor
High
ON
Rabbit
High speed, low driving torque in the travel motor
Summary of Contents for HX130 LCR
Page 11: ...1 1 SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10 ...
Page 174: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV ...
Page 536: ...8 108 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29 ...
Page 566: ...8 138 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10 ...