4-10
CHECK POINT
OPERATING FLOW
Warning flow
Alternator [CN-74 (
D+
)] I/conn [CN-6 (3)] MCU alternator level [CN-52 (27)]
Cluster charging warning lamp (via CAN interface)
Charging flow
Alternator "B+" terminal Starter motor [CN-45 (B+)]
Battery relay Battery (+) terminal
Circuit breaker [CN-60] Master switch [CS-74A] I/conn [CN-231 (2)]
Fuse box [No. 1~8]
Circuit breaker [CN-95] I/conn [CN-231 (1)] Fuse box [No. 14~28]
3. CHARGING CIRCUIT
When the starter is activated and the engine is started, the operator releases the starting switch to
the ON position.
Charging current generated by operating the alternator flows into the battery through the battery
relay [CR-1].
The current also flows from the alternator to each electrical component and controller through the fuse
box.
1)
2)
(1)
(2)
※
GND : Ground
Engine
Start switch
Check point
Voltage
RUN
ON
①
- GND (battery voltage)
②
- GND (battery relay)
③
- GND (alternator B+ terminal)
④
- GND (alternator D+ terminal)
⑤
- GND (MCU)