Step 6
Collect the following information and contact Huawei technical support personnel.
l
Results of the preceding troubleshooting procedure
l
Configuration files, log files, and alarm files of the AR2200-S
----End
Relevant Alarms and Logs
Relevant Alarms
None.
Relevant Logs
None.
6.1.8 A SIP AG Cannot Work Properly
Common Causes
This fault is commonly caused by one of the following:
l
The data configuration on the SIP AG is incorrect.
l
There is no reachable route between the AR2200-S and the softswitch.
l
Signaling packets are discarded on an intermediate device.
l
There are echoes or other environmental factors causing signal quality deterioration.
Troubleshooting Flowchart
shows the troubleshooting flowchart.