SDH error:
section layer: B1 0
line layer: B2 0 REI 44
path layer: B3 0 REI 23
Statistics last cleared:never
Last 300 seconds input rate 24 bits/sec, 0 packets/sec
Last 300 seconds output rate 24 bits/sec, 0 packets/sec
Input: 70945 packets, 1135144 bytes
Input error: 0 shortpacket, 0 longpacket, 0 CRC, 0 lostpacket
Output: 70945 packets, 1135140 bytes
Output error: 0 lostpackets
Output error: 0 overrunpackets, 0 underrunpackets
l
If the number of received or sent packets is 0, or the number does not increase, it indicates
that packets are discarded during transmission. Check whether the physical connection is
correct. For detailed information, see "Physical Interface Cannot Go Up".
l
If the physical connection is correct, you need to locate the cause of packet loss. For detailed
troubleshooting procedures, see "Packet Loss Troubleshooting".
l
If packets can be received and sent but the fault persists, go to
CAUTION
Debugging affects the system performance. Therefore, after debugging, run the
undo debugging
all
command to disable it immediately.
In addition, you can run the
debugging ppp all
interface
interface-type
interface-number
command to check the number of sent and received protocol packets and the status changes of
the PPP state machine.
Jun 2 2010 17:19:41.310.1 Huawei PPP/7/debug2:Slot=1;
PPP Event:
Serial2/0/0 LCP TO+(Timeout with counter > 0) Event
state acksent , Retransmit = 4
Jun 2 2010 17:19:41.310.2 Huawei PPP/7/debug2:Slot=1;
PPP Packet:
Serial2/0/0 Output LCP(c021) Pkt, Len 18
State acksent, code ConfReq(01), id 3, len 14
MRU(1), len 4, val 1176
MagicNumber(5), len 6, val 00abb891
Jun 2 2010 17:19:41.310.1 Huawei PPP/7/debug2:Slot=1;
PPP Packet:
Serial2/0/0 Input LCP(c021) Pkt, Len 18
State acksent, code ConfAck(02), id 3, len 14
MRU(1), len 4, val 1176
MagicNumber(5), len 6, val 00abb891
Jun 2 2010 17:19:41.310.2 Huawei PPP/7/debug2:Slot=1;
PPP Event:
Serial2/0/0 LCP RCA(Receive Config Ack) Event
state acksent
Step 4
Check that the link is loop-free.
Run the
display interface
interface-type
interface-number
command to check the physical status
of the interface.
[Huawei]
display interface Serial 2/0/0
Serial2/0/0 current state : UP
Line protocol current state : DOWN
Description:HUAWEI, AR Series, Serial 2/0/0 Interface
Route Port,The Maximum Transmit Unit is 4470, Hold timer is 10(sec)