If the client does not receive any response to its consecutive four heartbeat messages, it tears
down the link with the server. If the client has received heartbeat messages but the fault persists,
go to step 6.
Step 6
Collect the following information and contact Huawei technical support personnel.
l
Results of the preceding troubleshooting procedure
l
Configuration files, log files, and alarm files of the device
----End
Relevant Alarms and Logs
Relevant Alarms
None
Relevant Logs
None
5.7 PPP Troubleshooting
5.7.1 Protocol Status of a PPP Interface Is Down
Common Causes
After an interface is configured with PPP, LCP negotiation fails, which causes the protocol status
of the interface to be Down.
This fault is commonly caused by one of the following:
l
PPP configurations on the two ends of the link are incorrect.
l
The physical status of the interface is Down.
l
PPP packets are discarded.
l
A loop occurs on the link.
l
The link delay is too long.
Troubleshooting Flowchart
The troubleshooting roadmap is as follows:
l
Check that PPP configurations on the two ends of the link are correct.
l
Check that the physical status of the interface is Up.
l
Check that the interface can sent and receive protocol packets.
l
Check that the link is loop-free.
l
Check that the link delay is tolerant.
shows the troubleshooting flowchart.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
5 WAN
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
117