Figure 8-2
Troubleshooting flowchart: the PIM neighbor relationship remains Down
Enable PIM on the interface
Is fault rectified?
Change the PIM
configurations on the
interface
Seek technical support
Is fault rectified?
Is fault rectified?
End
Is fault rectified?
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No
No
The PIM neighbor
relationship remains
Down
Is PIM enabled
on the interface?
Is the PIM status
Up on the interface?
Are the PIM
configurations on the
interface correct?
Is the link status Up
on the interface?
Is the interface
physically Up?
Refer to the
troubleshooting of
interface Down
Refer to the
troubleshooting of
interface Down
Troubleshooting Procedure
NOTE
Saving the results of each troubleshooting step is recommended. If troubleshooting fails to correct the fault,
a record of the actions taken will exist to provide to Huawei technical support personnel.
Procedure
Step 1
Check that PIM is enabled on the interface.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
8 Multicast
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.