11-8
ES User’s Guide
Factory Preset State and Memory Allocation
Factory Preset and Peripheral States
Peripheral State
The analyzer is shipped from the factory with the settings in the
following table. These settings will remain as shown, until you change
them. When they have been changed and you then preset the analyzer
with the
hardkey, or the SCPI command "
SYST:PRESET
", or
cycle power, the settings are saved in non-volatile memory and thus are
not lost.
NOTE
These settings can be restored by pressing the
key several
times during power-up. This procedure clears all information in
non-volatile memory, including calibrations. Refer to the
key
definition on
for more information.
BEGIN Key Settings
MENU Key Settings
DISPLAY Key Settings
CAL Key Settings
SAVE RECALL Key Settings
1. Analyzers with Option 100 only
1. Option 100 only. For analyzers without Option 100, see
.
PRESET
User BEGIN menu
Off
Distance Units
1
Feet
Color options (for external monitor)
Factory default
Velocity factor
1
1.0 (speed of light)
Save ASCII format
Lotus
Select Disk
Non-Vol RAM disk
Volatile RAM disk percent
20%
IBASIC file type
ASCII
PRESET
PRESET
Summary of Contents for HP 8712ES
Page 8: ...viii ES User s Guide ...
Page 17: ...ES User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ES User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ES User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ES User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ES User s Guide 3 1 3 Making Measurements ...
Page 135: ...ES User s Guide 4 1 4 Using Instrument Functions ...
Page 159: ...ES User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 165: ...ES User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 224: ...4 90 ES User s Guide Using Instrument Functions Using an External VGA Monitor ...
Page 225: ...ES User s Guide 5 1 5 Optimizing Measurements ...
Page 246: ...5 22 ES User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 247: ...ES User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 281: ...ES User s Guide 7 1 7 Front Rear Panel ...
Page 306: ...7 26 ES User s Guide Front Rear Panel Line Module ...
Page 307: ...ES User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 410: ...8 104 ES User s Guide Hardkey Softkey Reference Z ...
Page 411: ...ES User s Guide 9 1 9 Specifications ...
Page 469: ...ES User s Guide 10 1 10 Safety and Regulatory Information ...
Page 475: ...ES User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 476: ...10 8 ES User s Guide Safety and Regulatory Information Regulatory Information ...
Page 477: ...ES User s Guide 11 1 11 Factory Preset State and Memory Allocation ...