5-4
ES User’s Guide
Optimizing Measurements
Increasing Sweep Speed
To Increase the Start Frequency
Since the analyzer sweeps frequencies below approximately 20 MHz at a
slower rate, you can increase the start frequency to speed up the sweep.
1. Press
.
2. Enter the highest start frequency possible for your measurement.
To Set the Sweep Time to AUTO Mode
Auto sweep time mode (the factory preset instrument mode) maintains
the fastest sweep speed possible for any particular measurement
settings.
1. Press
and look at the
softkey
label. When AUTO is all capital letters, it indicates that the analyzer
is in auto sweep time mode. If MAN is all capital letters, the analyzer
is in manual sweep time mode.
2. If necessary, press
to toggle the time mode
to AUTO.
To Widen the System Bandwidth
Press
to widen the IF bandwidth. As the
bandwidth increases, the sweep speed gets faster and the trace noise
increases.
Table 5-1
Relationship between System Bandwidth and Sweep Speed
FREQ
Start
SWEEP
Sweep Time AUTO man
Sweep Time auto MAN
AVG
System Bandwidth
System Bandwidth
Sweep Speed
Wide
Medium Wide
Medium
Medium Narrow
Narrow
Fine
fastest
faster
fast
slow
slower
slowest
Summary of Contents for HP 8712ES
Page 8: ...viii ES User s Guide ...
Page 17: ...ES User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ES User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ES User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ES User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ES User s Guide 3 1 3 Making Measurements ...
Page 135: ...ES User s Guide 4 1 4 Using Instrument Functions ...
Page 159: ...ES User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 165: ...ES User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 224: ...4 90 ES User s Guide Using Instrument Functions Using an External VGA Monitor ...
Page 225: ...ES User s Guide 5 1 5 Optimizing Measurements ...
Page 246: ...5 22 ES User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 247: ...ES User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 281: ...ES User s Guide 7 1 7 Front Rear Panel ...
Page 306: ...7 26 ES User s Guide Front Rear Panel Line Module ...
Page 307: ...ES User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 410: ...8 104 ES User s Guide Hardkey Softkey Reference Z ...
Page 411: ...ES User s Guide 9 1 9 Specifications ...
Page 469: ...ES User s Guide 10 1 10 Safety and Regulatory Information ...
Page 475: ...ES User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 476: ...10 8 ES User s Guide Safety and Regulatory Information Regulatory Information ...
Page 477: ...ES User s Guide 11 1 11 Factory Preset State and Memory Allocation ...