8-56
ES User’s Guide
Hardkey/Softkey Reference
M
Softkey in the display frequency resolution menu and the numeric
entry menu.
When pressed in the display frequency resolution menu, displays the
frequency to MHz resolution. For example, 1.234 567 MHz is displayed
as 1 MHz (note rounding down).
Access Keys:
Softkey in the edit limit (min/max) menu. Use this key to set the
minimum limit for the marker limit function that is currently
highlighted in the on-screen table.
See
“To Use Marker Limit Functions” on page 4-32
information.
Access Keys:
Softkey in the marker search menu. Places the active marker at the
frequency point of minimum amplitude. If tracking is off, the marker
remains at that frequency. If tracking is on, the marker moves to the
minimum point with each sweep.
See
Access Keys:
Softkey in the
menu. Displays the menu with selections
suitable for mixer and frequency converter measurements: conversion
loss and S
11
.
See
“Measuring Conversion Loss” on page 3-61
conversion loss measurement.
Softkey in the annotation options menu. Toggle to ON if you want to
view the marker information in the upper right corner of the display.
See
“Customizing the Display” on page 4-45
Access Keys:
MHz
FREQ
Disp Freq Resolution
Min Limit
DISPLAY
Limit Menu Mkr Limits
Edit Limit (Min/Max)
Min Search
MARKER
Marker Search
Mixer
BEGIN
Mkr Annot
ON off
DISPLAY
More Display Annotation Options
Summary of Contents for HP 8712ES
Page 8: ...viii ES User s Guide ...
Page 17: ...ES User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ES User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ES User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ES User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ES User s Guide 3 1 3 Making Measurements ...
Page 135: ...ES User s Guide 4 1 4 Using Instrument Functions ...
Page 159: ...ES User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 165: ...ES User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 224: ...4 90 ES User s Guide Using Instrument Functions Using an External VGA Monitor ...
Page 225: ...ES User s Guide 5 1 5 Optimizing Measurements ...
Page 246: ...5 22 ES User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 247: ...ES User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 281: ...ES User s Guide 7 1 7 Front Rear Panel ...
Page 306: ...7 26 ES User s Guide Front Rear Panel Line Module ...
Page 307: ...ES User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 410: ...8 104 ES User s Guide Hardkey Softkey Reference Z ...
Page 411: ...ES User s Guide 9 1 9 Specifications ...
Page 469: ...ES User s Guide 10 1 10 Safety and Regulatory Information ...
Page 475: ...ES User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 476: ...10 8 ES User s Guide Safety and Regulatory Information Regulatory Information ...
Page 477: ...ES User s Guide 11 1 11 Factory Preset State and Memory Allocation ...