
ES User’s Guide
8-67
Hardkey/Softkey Reference
P
Softkey in the mod kit save/recall menu. Presets all of the User Cal
Kits to the type-N(f) calibration kit. This reduces the size of your saved
instrument state since user-defined calibration kits (Cal Kits A–J)
aren’t included in the saved information.
See
“Calibration Kits” on page 6-23
for more information.
Access Keys:
Softkey in the mod kit save/recall menu. Presets the selected User Cal
Kit to the type-N(f) calibration kit. This reduces the size of your saved
instrument state since the user-defined calibration kit isn’t included in
the saved information.
See
“Calibration Kits” on page 6-23
for more information.
Access Keys:
Softkey in the more printer menu. Sets print width (printing space) in
mm.
See
“Connecting and Configuring Printers and Plotters” on page 4-68
for more information.
Access Keys:
Softkey in the select copy port menu. Sets the recognized address of
HP-IB printers and plotters only. The default address is 5. The
"recognized HP-IB address" is the address that the network analyzer
uses to communicate with the device. The actual address of the device
must be set independently to match.
See
“Connecting and Configuring Printers and Plotters” on page 4-68
for more information.
Access Keys:
Preset All
User Kits
CAL
More Cal Cal Kit Modify (connector type)
Mod Kit SaveRecall
Preset
User Kit
CAL
More Cal Cal Kit Modify (connector type)
Mod Kit SaveRecall
Print Width
HARDCOPY
Define Printer More Printer
Print/Plot
HP-IB Addr
HARDCOPY
Select Copy Port
Summary of Contents for HP 8712ES
Page 8: ...viii ES User s Guide ...
Page 17: ...ES User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ES User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ES User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ES User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ES User s Guide 3 1 3 Making Measurements ...
Page 135: ...ES User s Guide 4 1 4 Using Instrument Functions ...
Page 159: ...ES User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 165: ...ES User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 224: ...4 90 ES User s Guide Using Instrument Functions Using an External VGA Monitor ...
Page 225: ...ES User s Guide 5 1 5 Optimizing Measurements ...
Page 246: ...5 22 ES User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 247: ...ES User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 281: ...ES User s Guide 7 1 7 Front Rear Panel ...
Page 306: ...7 26 ES User s Guide Front Rear Panel Line Module ...
Page 307: ...ES User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 410: ...8 104 ES User s Guide Hardkey Softkey Reference Z ...
Page 411: ...ES User s Guide 9 1 9 Specifications ...
Page 469: ...ES User s Guide 10 1 10 Safety and Regulatory Information ...
Page 475: ...ES User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 476: ...10 8 ES User s Guide Safety and Regulatory Information Regulatory Information ...
Page 477: ...ES User s Guide 11 1 11 Factory Preset State and Memory Allocation ...