ES User’s Guide
8-5
Hardkey/Softkey Reference
A
A
Softkey in the narrowband internal menu. Selects the tuned receiver
measurement of input A.
See
“Measuring Devices with Your Network Analyzer” on page 3-3
more information on input A.
Access keys:
or
,
Softkey in the narrowband internal menu. Selects the tuned receiver
reflection measurement A/R.
See
“Measuring Devices with Your Network Analyzer” on page 3-3
more information on measuring A/R.
Access keys:
or
,
Softkey in the
menu. Stops sending data from the
network analyzer to the hardcopy device.
NOTE
Hardcopy devices with large buffers may continue
to operate for quite a while after this command.
To stop such devices immediately, turn off power
to the hardcopy device.
Softkey in the modify kit menu. Stops the current calibration kit
modification procedure and returns to the cal kit menu.
Access Keys:
Softkey in the marker menu that turns off the active marker and
makes the lowest numbered marker (if any) the active marker.
See
for an explanation of "active marker,"
and for more information on using markers.
Access Keys:
A
MEAS 1
MEAS 2
More Detection Options
Narrowband Internal
A/R
MEAS 1
MEAS 2
More Detection Options
Narrowband Internal
Abort
HARDCOPY
Abort Kit
CAL
More Cal Cal Kit
Modify (connector type)
Active
Marker Off
MARKER
More Markers
Summary of Contents for HP 8712ES
Page 8: ...viii ES User s Guide ...
Page 17: ...ES User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ES User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ES User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ES User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ES User s Guide 3 1 3 Making Measurements ...
Page 135: ...ES User s Guide 4 1 4 Using Instrument Functions ...
Page 159: ...ES User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 165: ...ES User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 224: ...4 90 ES User s Guide Using Instrument Functions Using an External VGA Monitor ...
Page 225: ...ES User s Guide 5 1 5 Optimizing Measurements ...
Page 246: ...5 22 ES User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 247: ...ES User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 281: ...ES User s Guide 7 1 7 Front Rear Panel ...
Page 306: ...7 26 ES User s Guide Front Rear Panel Line Module ...
Page 307: ...ES User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 410: ...8 104 ES User s Guide Hardkey Softkey Reference Z ...
Page 411: ...ES User s Guide 9 1 9 Specifications ...
Page 469: ...ES User s Guide 10 1 10 Safety and Regulatory Information ...
Page 475: ...ES User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 476: ...10 8 ES User s Guide Safety and Regulatory Information Regulatory Information ...
Page 477: ...ES User s Guide 11 1 11 Factory Preset State and Memory Allocation ...