Ranging
(continued)
•
Front-Panel Operation
: Use the front-panel
RANGE
keys to select
autoranging or manual ranging. For frequency and period
measurements from the front panel, ranging applies to the signal’s
input
voltage
, not its frequency.
See also “To Select a Range,” on page 20.
•
Remote Interface Operation
: You can set the range using any of the
following commands.
CONFigure:<
function
> {<
range
>|MIN|MAX|DEF},{<
resolution
>|MIN|MAX|DEF}
MEASure:<
function
>? {<
range
>|MIN|MAX|DEF},{<
resolution
>|MIN|MAX|DEF}
<
function
>:RANGe {<
range
>|MINimum|MAXimum}
<
function
>:RANGe:AUTO {OFF|ON}