233
E
E
F
G
H
I
J
K
L
M
N
8.5 Options
Hygiene design
■
Fresh air filter class F7
■
Extract air filter class F5
Fans with variable air flow rate VAR
■
Maintenance-free, direct-drive supply air fan with
frequency converter
■
Maintenance-free, direct-drive exhaust air fan with
frequency converter
High-pressure fan supply air HZ
Maintenance-free, direct-drive high-pressure fan supply air
High-pressure fan exhaust air HF
Maintenance-free, direct-drive high-pressure exhaust air fan
Hydraulic assembly diverting system HG
Prefabricated assembly for hydraulic diverting system,
consisting of magnetic mixing valve, balancing valve, ball
valve, automatic air vent and screw connections for connec-
tion to the unit and to the distributor circuit; ready-to-connect
mixing valve for connection to the connection box; sized for
the respective heating coil and the Hoval DigiNet control
system
Magnetic mixing valve ..HV
Continuous regulating valve with magnetic drive, ready for
connection to the connection box, sized for the respective
heating coil
Fresh air silencer ASD
As an attachment to the weather louvre door, casing
consisting of Aluzinc sheet steel with lining of sound attenu-
ation material, for reducing noise from the weather louvre
door, insertion attenuation _____ dB
Exhaust air silencer FSD
As an attachment to the exhaust air grille, casing consisting
of Aluzinc sheet steel with built in sound attenuation splitters,
for reducing the noise from the exhaust air grille, insertion
attenuation _____ dB
Supply air silencer ZSD
As an inserted component in the below-roof unit, casing
consisting of Aluzinc sheet steel with built in sound attenu-
ation splitters, for reducing the noise in the room, insertion
attenuation _____ dB
Extract air silencer ABSD
As an attachment to the extract air grille, casing consisting
of Aluzinc sheet steel with built in sound attenuation split-
ters, for reducing the noise in the room, insertion attenuation
_____ dB
Acoustic cowl AHD
Consisting of an absorber hood of large volume and a screen
with a lining of sound attenuation material, insertion attenua-
tion 4 dB
Actuator with spring return SMF
Continuous actuators with safety function in case of a power
failure, mounted and wired on the fresh air damper
Air outlet box AK
Consisting of Aluzinc sheet steel, with four adjustable
exhaust air grilles (replaces the Air-Injector)
Design for injection system ES
Control and high-voltage section for the heating pump inte-
grated into the DigiUnit terminal box
RoofVent
®
LH
Specification texts
Summary of Contents for RoofVent CON-9
Page 2: ......
Page 4: ...2...
Page 6: ...4...
Page 8: ...6...
Page 12: ...10 RoofVent LHW Use...
Page 40: ...38 RoofVent LKW Use...
Page 68: ...66 RoofVent twin heat Use...
Page 94: ...92 RoofVent twin cool Use...
Page 122: ...120 RoofVent twin pump Use...
Page 150: ...148...
Page 154: ...152 RoofVent condens Use...
Page 180: ...210 RoofVent LH Construction and operation...
Page 208: ...238 RoofVent LK Use...
Page 256: ...286...
Page 268: ...298...
Page 274: ...304...
Page 279: ......