HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – °C/QUANTITY menu
95
✎
See “Procedure” in this section.
F
IXED
VALUE
- S
ETTING
THE
FUEL
AND
AIR
QUANTITY
This submenu is used to set the “fixed value” control options.
✎
See “Procedure” in this section.
Material Type
2-05
Fuel
1 : ( Fuel 1 )
END
The standard setting for start-up is usually
Fuel: 1
.
Independent modification of settings for adapting to the fuel
should be made under another fuel type so as not to change the
startup settings. For example, save the start-up setting under
Fuel: 2
and only then modify this setting.
Settings fixed value
2-06
Fuel
: 60.0 /55.0 %
Primary air :
30 /
30 %
Secondary air :
30 /
15 %
Comb. chamb. temp.
:
600 / 411 °C
END
In this menu, the settings of the fuel and air quantities are fixed
value presets for “Fixed value” operation only.
✎
See section “6.6 ON/OFF menu”, under “Setting the control,
boiler activation and Lambda Stop”.