4 Planning and installation – Installing the heating system
49
1. Place the seal (4) on the insertion flange (5).
2. Push the stoker pipe (3) onto the insertion flange (5).
3. Fasten the stoker pipe (3) with the M12 nuts (19 mm spanner).
4. Bolt the support leg (2) onto the stoker pipe (3) with the M12
screws (19 mm spanner).
5. Fix the support leg (2) to the floor if necessary (screws and screw
anchors are not included in the scope of delivery).
6. Mount the rotary wheel (1) on the stoker pipe connection with the
M12 screws (19 mm spanner).
✓
The HDG feeding system TBZ 200 is installed.
HDG TBZ 150
1. Place the seal (13) on the insertion flange (15).
2. Fasten the adapter piece (12) to the insertion flange (15) with the
M12 nuts (19 mm spanner).
3. Slide the adapter pipe (8) with the seal (9) into the feed channel
(10).
4. Align the seal (9) with the holes.
Warning!
Danger of injury
The feeding system is very heavy. Hands and feet could be crushed
when it is lifted.
Only lift the feed system using suitable lifting equipment.
Figure 4/13 - Installing the feeding system TBZ 150
1
9
6
5
4
3
2
8
7
10
14
11
13
15
12