8 Troubleshooting – Possible faults
160
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
FA070
Dosage
container
overfilling
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical
connection
•
Eliminate material blockage
FA071
Foreign bodies
in rotary feeder
•
Foreign bodies in feed
system or stoker auger
•
Transformer in control
cabinet faulty
•
Motor is faulty
•
Check for foreign bodies
•
Moving forwards and
backwards in the manual
menu
•
Check transformer in control
cabinet
•
Check the motor
FA073
Fuel storage
door end switch
•
Fuel storage door was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Close the door
•
Check limit switch
•
Check the cable
•
Check the electrical
connection
FA074
Check material
stop limit
switch
•
Limit switch triggered 1
filling at start
•
Checking the fill level
indicator
ST075
Foreign bodies
in rotary feeder
2
•
Foreign bodies in feed
system or stoker auger
•
Transformer in control
cabinet faulty
•
Motor is faulty
•
Check for foreign bodies
•
Moving forwards and
backwards in the manual
menu
•
Check transformer in control
cabinet
•
Check the motor
FA077
Pellet auger
overfilling
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical
connection
•
Eliminate material blockage
FA078
Overfilling of
pellet auger at
tube converter
position 1
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical
connection
•
Eliminate material blockage
FA079
Overfilling of
pellet auger at
tube converter
position 2
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical
connection
•
Eliminate material blockage
No.
Fault
Cause
Remedy
Table 8/1 - Faults (continuation)
Summary of Contents for M299
Page 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Page 2: ......
Page 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 173: ...173 NOTICE ...
Page 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 175: ......