6 Using the heating system – SERVICE menu
110
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
•
ST Full ash box
When the preset runtime of the ash removal auger is exceeded, the
fault message “
Ash box full
” appears. The heating system shuts
off at this fault. The “0” setting deactivates this function.
•
Emptying WA fly ash container
When the preset runtime of the ash removal auger is exceeded, the
warning “
Please empty fly ash container
” appears. The
heating system does not shut off at the appearance of this warning.
The “0” setting deactivates this function.
1.
Open the
Service 5-02
submenu.
✎
See “Procedure” in this section.
2.
Using the
F1
key select
service messages 11-04
in the
submenu.
3.
Press the
F5
key under the
RESET
command to reset the times.
S
ERVICE
MESSAGES
3 -
SETTING
REMINDER
TIME
•
Filling WA_1 fuel storage room
When the preset runtime of the ash removal auger is exceeded, the
warning “
Please fill fuel storage room soon
” appears.
The heating system does not shut off at the appearance of this
warning. The “0” setting deactivates this function.
•
Filling WA_2 fuel storage room
When the preset runtime of the ash removal auger is exceeded, the
warning “
Fill fuel storage room
” appears. The heating
system does not shut off at the appearance of this warning. The “0”
setting deactivates this function.
•
Perform WA_1 Service
When the preset runtime of the ash removal auger is exceeded, the
warning “
Perform service soon
” appears. The heating system
does not shut off at the appearance of this warning. The “0” setting
deactivates this function.
•
Perform WA_2 Service
Service messages
11-04
ST Empty ash box:
0.0/ 0.0 m
ST Empty ash box:
0.0/ 0.0 m
Empty WA fly ash container
:
0.0/ 0.0
m
RESET
END
Summary of Contents for M299
Page 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Page 2: ......
Page 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 173: ...173 NOTICE ...
Page 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 175: ......