3 Mode of operation – Fuel quality requirements
24
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
*Maximum operating temperatures of up to 110 °C can also briefly
occur.
3.4 Fuel quality requirements
P
ERMISSIBLE
FUEL
The HDG M299/300/350/400 heating system is designed for the
standard use of burning untreated wood in the form of wood chips,
shavings and wood pellets.
In accordance with German law (§3 (1) 1. BlmSchV), the fuel classes 4,
5, 5a, 6, and 7 may be used in this heating system.
F
UEL
CLASS
4
Untreated log wood including adhering bark in the form of wood
chips.
F
UEL
CLASS
5
Untreated wood (not log wood), such as shavings.
F
UEL
CLASS
5
A
Pellets made of untreated wood in the form of wood pellets or wood
briquettes
F
UEL
CLASS
6
Painted, varnished or coated wood including remains thereof,
provided no wood protection agents have been applied or are
present as the result of a treatment, and coatings do not contain
organic halogen compounds or containing heavy metals.
F
UEL
CLASS
7
Plywood, chipboard, fibreboard or otherwise glued wood including
remains thereof, provided no wood protection agents have been
applied or are present as the result of a treatment, and coatings do
not contain organic halogen compounds or heavy metals.
Fuel classes 6 or 7 may only be used in a wood processing plant at 30
kW or more nominal thermal power. In the case of painted, varnished
or coated wood, it should be noted that greater stress can be placed
on the wearing parts such as wall lining, fill level and lambda sensors,
which may reduce their service lives.
Water-side resistance at nominal
thermal power
•
10 K
•
20 K
9100 Pa
2500 Pa
9100 /
10200 Pa
2500 /
2800 Pa
11500 /
13100* Pa
3100 /
3500* Pa
14600 Pa
4000 Pa
Other information
Sound pressure level emitted
< 70 dB(A)
Min. air inlet cross section
648 cm²
670 /
700 cm²
750 /
750 cm²
850 /
850 cm²
Boiler type
HDG M299
Wood chips
HDG M300
Wood chips /
pellets
HDG M350
Wood chips /
pellets
HDG M400
Wood chips /
pellets
Table 3/1 - Technical data
Summary of Contents for M299
Page 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Page 2: ......
Page 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 173: ...173 NOTICE ...
Page 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 175: ......