HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – SERVICE menu
113
•
Feeding unit lag time
– This parameter determines the lag time of the rotary feeder
and the stoker auger. The continued running empties the
auger channel when the heating system is shut off.
•
Feeding unit lead time
– After a prior Lambda stop, combustion chamber temperature
stop or material stop, the rotary wheel starts earlier than the
delivery system by the period of the preset value.
✎
See “Procedure” in this section.
F
UEL
QUANTITY
1
ST
M
ODIFYING
FILLING
AND
AIR
START
SETTING
•
Fuel quantity 1st filling
Change the fuel quantity of the first filling in heating up mode.
•
Air start setting
These parameters determine the air quantity of the primary air and
secondary air for heating up mode.
✎
See “Procedure” in this section.
I
GNITION
FAN
You can set the phase and form in which the ignition fan is switched
on to aid the start-up procedure. Three settings are available in each
phase:
– Off: The ignition fan is not yet activated in this phase.
– Fan: Only the fan of the ignition fan is activated.
Service
5-05
Dosage pause_min. : 3.0 /
3.0 s
Dosage pause_min. : 3.0 /
4.5 s
Feeding unit lag time
: 2.0 /
s
Feed system lead time : 2.0 s
END
Service
5-06
Fuel quantity 1st filling :
25.0 %
Primary air start
:
15 %
Secondary air start :
30 %
END
Summary of Contents for M299
Page 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Page 2: ......
Page 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 173: ...173 NOTICE ...
Page 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Page 175: ......