6 Using the heating system – ON/OFF menu
90
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
C
HANGING
THE
CLEANING
SYSTEM
SETTING
The automatic heat exchanger cleaning system can be switched off.
✎
See “Procedure” in this section.
M
ODIFYING
THE
EXTRACTION
SETTING
The heating system can, for example, include a separate delivery
system for a shaving silo. In addition, the flexi-blade delivery system
can be employed for extraction in combination with an additional
conveyor auger. Extraction can be controlled in various ways.
•
Cycles
In this version, the extraction runs in a cycle with configurable pause
intervals and runtimes.
✎
For setting options, see the section “6.8 TIME menu” in this
chapter.
•
Continuous running
In this version, the extraction runs continuously upon demand.
✎
See “Procedure” in this section.
Setting
1-05
Cleaning system
: On
CHOOSE
END
The standard setting is
On
.
Setting
1-06
Delivery system
: Continuous running
CHOOSE
END
The standard setting is
Continuous
.