Installation and commissioning
Installation of cables
5.4.2
Rules for cable installation
Install all the cables according to the mechanical
requirements in a way which prevents them from
getting damaged!
Secure the cables sufficiently according to the
requirements. Where necessary, provide suitable
strain relief!
Do not install the cables without taking suitable
measures to protect them from damage or lay
them over edges with direct mechanical contact!
It is important that you observe the specified
minimum bending radius when installing the
cables!
Minimum bending radius
y
With flexible installation:
R
min.
= 10 x 0
y
With permanent installation: R
min.
= 4 x 0
5.4.3
Requirements on the connection cables
As usual, select all connection cables in accordance with the electrical and
mechanical requirements.
Only use the supplied cables which were pre-assembled in the factory, or
cable types expressly permitted by GTS.
Minimum requirements for the cables used
y
UV-resistant,
y
abrasion resistant,
y
highly-flexible,
y
oil-resistant,
y
resistant to high alternating bending stress.