ts
Transport and storage
General
9
Transport and storage
9.1
General
To protect the generator against damage, the generator of the
i
MAPLA
system is bolted down for transport on a pallet ex works. The MMI and
connecting cables are enclosed.
Only transport and store the generator.
Note
►
Transport and store the
i
MAPLA system when dry and
protected from water.
►
Only transport or store the
i
MAPLA system in the
as-delivered condition with packaging and protection
devices fitted.
►
Close the protective covers provided for this purpose,
attach the sealing caps, and seal correctly.
9.2
Ambient conditions for transport and storage
Permissible temperatures:
Transport
-25 °C to +60 °C
Storage
-20 °C to +50 °C
Permissible relative humidity:
Transport
95 %, non-condensing
Storage
95 %, non-condensing
9.3
Lifting generators and switch boxes
Only use suitable lifting equipment to lift the generators.
iMAPLA 8, 13 and 17, construction type “One Unit”
To lift these generators on the front and rear side of the generator,
X a load-bearing cable under the attached switch box. Weights: 64 kg for
i
MAPLA 8, 75 kg for
i
MAPLA 13, 96 kg for
i
MAPLA 17.