Installation and commissioning
Generator installation for iMAPLA 25 and 30
>
Secure the drive side of the coupling
[4]
to the drive and insert it into the
coupling plate. If necessary, while inserting, twist slightly until the gearing
locks.
>
Secure the flange
[1]
to the drive unit.
2a
2b
M12x35
DIN912
DIN128
A-12
4
3
2a
2b
1
4x
2a
M12 x 35 DIN 912
2b
A-12 DIN 128
Fig. 31 Assembly of flange mount SAE5 (iMAPLA 25 and 30)
5.6.7
Assembly instructions for hydraulic drive
Preparatory disassembly
Ö
Fig. 30, Preparatory disassembly of the flange mount SAE5
>
Carry out the preparatory disassembly on the generator.
Ö
Assembly instructions for flange mount SAE5, page 86