Installation and commissioning
Generator installation for iMAPLA 8, 13, 17 and 20
y
Secure the generator with at least four mounting screws
(minimum M8 or comparable, bolt grade
min. 8.8).
y
The attachment must be permanent and
resistant to shock and vibrations.
y
Use suitable means to prevent the screws
from coming undone by themselves,
e.g. via a tension ring according to DIN 128.
Tightening torque for mounting screws
M = 25 Nm
Permissible load on the shaft
Fr
max
=
2,000 N for
i
MAPLA 8 and 13
Fr
max
=
3,000 N for
i
MAPLA 17 and 20
(measured in a 50 mm axial clearance
from the point where the shaft exits
the bearing plate.
Fa
max
=
200 N for
i
MAPLA 8 and 13
Fa
max
=
380 N for
i
MAPLA 17 and 20
Important
►
Do not attach any third party parts to
the mounting profiles on the generator
housing.
5.5.4
Minimum clearances and cooling provisions
y
The generator needs sufficient ventilation for cooling. The cooling air is
drawn through the cooling profiles by the fan wheel on the rear side of the
generator and across the housing, towards the front side.
y
Ensure adequate air feed and exhaust openings.
y
Comply with the following minimum clearances and note the regulations
for cooling.
4 Mounting screws
Fr
Fa
max
max