Example for
blink code no. 3:
(LED flashes three
times
Count value = Code 3)
LED OFF
LED ON
Time
Pause LED OFF
Note: On the
i
MAPLA 2013 series, the description of blink codes 8 to 10 is
different. Here the
i
MAPLA 2013 series is to be indicated as “G2”. All other
systems as “G1”.
= 3 x brief ON
= 3 x brief ON
Blink code
(Number)
Brief description
i
MAPLA G1/G2
extended error description
Class / Category
Description / procedure
1
not assigned
---
---
not assigned
2
Clocking
mechanism / discharger
Fault
A clock fault is detected with the degaussing procedure and afterwards
an emergency function is switched to active
internal system fault
Category 1
Clocking mechanism / discharger fault
Notify after-sales service
3
Limiter Overload
The permitted limiter limit of
>130
% of the rated load of the machine
was exceeded. The re-engaging lock is active. Check the load, connect
smaller load where necessary.
external system fault
Category 1
overload too large!
Make sure that a suitable lifting magnet was connected. Check the lifting magnet
for winding short circuits and other faults
4
Short circuit type 1
Conductance monitor triggered
external system fault
Category 1
Short circuit present at output; check lifting magnet and load cable
5
Short circuit type 2
Limit monitor triggered
external system fault
Category 1
high magnetic current lead to the short-circuit disconnection; check the lifting
magnet and load cable
6
Short circuit type 3
IGBT desaturation monitor triggered
internal system fault
Category 2
critical short circuit present; check the lifting magnet and load cable; if this fault
continues, contact customer service
7
Short circuit type 4
Undervoltage monitor
triggered
external system fault
Category 2
soft (creeping) short circuit or overload >400 % of the rated load at the output;
check lifting magnet and load cable
8
G1
Overvoltage type 1
Overvoltage in the intermediate circuit
internal system fault
Category 2
Overvoltage controller
Notify after-sales service
8
G2
Overtemperature
Overtemperature, electronics
internal system fault
Category 2
Overtemperature of the electronics -> critical value, check ventilation
9
G1
Overvoltage Type 2
Overvoltage in the intermediate circuit
internal system fault
Category 2
Overvoltage controller
Notify after-sales service
9
G2
Generator fault
Generator fault or loose contact on the generator connector
internal system fault
Category 2
Phase failure of generator or loose connector contact, contact customer services
10
G1
Overvoltage Type 3
Overvoltage generator in idle
internal system fault
Category 2
Overvoltage controller,
Notify after-sales service
10
G2
Electronics fault
Electronics fault in the controller
internal system fault
Category 2
Electronics fault, internal reference voltage, notify customer services
11
System fault
Internal system fault
internal
system fault
not defined (free)
no blink
code
no intelligent MAPLA
present
the older software version of the MAPLA does not support this function
---
Function not available due to older software version of the MAPLA / software
update possible