K2 Media Server failover with Control team failover behavior
K2 RAID
K2 Media
Servers
K2 SAN-attached systems
Ethernet
switches
A
A
B
B
Fibre Channel
connections
Control
Media
Control
Media
Control
FTP
Media
Control
FTP
Media
ISLs
X
Component
Failure
If the following system connection or component fails to respond to network communication:
•
The “A” GigE switch
Then the following failover behavior occurs:
1. The media file system (SNFS) and media database on K2 Media Server “A” fail over and K2
Media Server “B” becomes the active media file system/metadata server.
2. All K2 SAN-attached systems drop communication on the “A” media port and begin using the
“B” media port, finding a path through GigE switch “B” to K2 Media Server “B”. All K2
SAN-attached systems use an iSCSI adapter (TOE) on the “B” K2 Media Server to provide
access to the Fibre Channel connected RAID storage.
3. For all K2 SAN-attached systems, communication fails on the control port, so the control team
fails over and communication begins on the other control port.
4. For all K2 SAN-attached systems, control communication finds a path through GigE switch “B”
to K2 Media Server “B”.
2014 01 27
K2 SAN Installation and Service Manual
247
Operating the K2 SAN
Summary of Contents for K2 SAN
Page 2: ......
Page 4: ......
Page 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Page 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Page 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Page 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Page 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...