4 - 48
S-60 • S-65 • S-60 TRAX • S-65 TRAX
Part No. 147753
S-60 HC • S-60X • S-60XC
December 2013
Section 4 • Repair Procedures
Function Manifold Components
,
continued
I
ndex
Schematic
No.
Description
Item
Function
Torque
19
Check valve, 5 psi / 0.3 bar ............... A ........... Blocks flow from auxiliary pump
to function pump ............................... 30-35 ft-lbs / 41-47 Nm
20
Relief valve, 3000 psi / 206.8 bar ..... K ........... System relief ..................................... 30-35 ft-lbs / 41-47 Nm
21
Flow control valve,
0.1 gpm / 0.38 L/min .......................... DD ........ Bleeds off differential sensing
valves to tank .................................... 20-25 ft-lbs / 27-34 Nm
22
Differential sensing valve,
150 psi / 10.3 bar .............................. CC ........ Differential sensing circuit,
meters flow to functions .................... 30-35 ft-lbs / 41-47 Nm
23
Check valve ....................................... W .......... Differential sensing circuit,
platform level up ............................... 10-12 ft-lbs / 14-16 Nm
24
Check valve ....................................... X ........... Differential sensing circuit,
platform level down .......................... 10-12 ft-lbs / 14-16 Nm
25
Proportional solenoid valve .............. Q ........... Turntable rotate left/right .................. 20-25 ft-lbs / 27-34 Nm
26
Flow control valve,
0.6 gpm / 2.27 L/min .......................... Z ........... Platform rotate and
jib boom (S-65, S-65 TRAX) ............. 20-25 ft-lbs / 27-34 Nm
27
Check valve, 30 psi / 2 bar ................ EE ......... Platform rotate and jib
boom circuit (S-65, S-65 TRAX)
(prevents hydraulic hoses
from draining back to tank) ............... 20-25 ft-lbs / 27-34 Nm
28
Differential sensing valve,
110 psi / 7.6 bar ................................. L ........... Boom extend/retract circuit ............... 30-35 ft-lbs / 41-47 Nm
29
Needle valve ..................................... U ........... Platform level circuit ......................... 30-35 ft-lbs / 41-47 Nm
30
Solenoid valve, 3 position 4 way ...... V ........... Platform level up/down ..................... 20-25 ft-lbs / 27-34 Nm
31
Solenoid valve, 3 position 4 way ...... Y ........... Platform rotate and jib boom
up/down (S-65, S-65 TRAX) ............. 20-25 ft-lbs / 27-34 Nm
MANIFOLDS
Summary of Contents for S-60 HC
Page 1: ......
Page 215: ...Section 6 Schematics December2013 6 7 Ford DSG 423 Engine Wire Harness 6 8 ...
Page 218: ...December2013 Section 6 Schematics 6 10 Ford MSG 425 Engine Wire Harness 6 9 ...
Page 219: ...Section 6 Schematics December2013 6 11 Electrical Schematic Options All Models 6 12 ...
Page 222: ...December2013 Section 6 Schematics 6 14 Wiring Diagram Belt Driven Generator 6 13 ...
Page 223: ...Section 6 Schematics December2013 6 15 Wiring Diagram 3kW Hydraulic Generator 6 16 ...
Page 234: ...December2013 Section 6 Schematics 6 26 Hydraulic Schematic 2WD Models after SN 21396 6 25 ...
Page 238: ...December2013 Section 6 Schematics 6 30 Hydraulic Schematic 4WD Models after SN 21396 6 29 ...
Page 365: ...Section 6 Schematics December2013 6 157 Electrical Schematic S 60 HC CE 6 158 ...
Page 368: ...December2013 Section 6 Schematics 6 160 Chassis Wiring Diagram S 60 HC CE 6 159 ...
Page 373: ...Section 6 Schematics December2013 6 165 Platform Control Box Wiring Diagram S 60 HC CE 6 166 ...
Page 461: ......