5 - 22
S-60 • S-65 • S-60 TRAX • S-65 TRAX
Part No. 147753
S-60 HC • S-60X • S-60XC
December 2013
Section 5 • Fault Codes
Error Source 12, System Checks
Error Type
Condition
Solution
ID Name
11 Safety envelope reached
Power relays disengaged.
Use recovery switch and APU from the
ground controls to recover the
machine to stowed position or within the
operating envelope.
12 Platform load greater
Power relays disengaged.
Remove weight from platform until load is
than 1250 lbs/567 kg
1200 lbs/544 kg or less.
13 CAN communication failure
Power relays disengaged.
Repair CAN bus wiring and/or
connections.
14 Sensor power failure
Power relays disengaged.
Use recovery switch and APU from the
ground controls to recover the machine
to stowed position or within the operating
envelope.
21 Angle sensor
Power relays disengaged.
Inspect boom angle sensor for
not active
proper operation and be sure it is
connected to boom properly OR replace
boom angle sensor.
22 String potentiometer
Power relays disengaged.
Inspect string potentiometer for proper
not active
operation and be sure it is connected to
boom properly OR replace string
potentiometer.
23 Power relay output
Power relays disengaged.
Repair system wiring and/or connections.
short high
Relay wiring open or
shorted to voltage.
24 Power relay output
Power relays disengaged.
Repair system wiring and/or connections.
short low
Relay wiring open or
shorted to ground.
25 Directional relay output
Boom up/down and
Repair system wiring and/or connections.
short high
extend/retract inoperative.
Relay wiring open or
shorted to voltage.
26 Output short low
Boom up/down and
Repair system wiring and/or connections.
extend/retract inoperative.
Relay wiring open or
shorted to ground.
Load Sense System Fault Codes
Summary of Contents for S-60 HC
Page 1: ......
Page 215: ...Section 6 Schematics December2013 6 7 Ford DSG 423 Engine Wire Harness 6 8 ...
Page 218: ...December2013 Section 6 Schematics 6 10 Ford MSG 425 Engine Wire Harness 6 9 ...
Page 219: ...Section 6 Schematics December2013 6 11 Electrical Schematic Options All Models 6 12 ...
Page 222: ...December2013 Section 6 Schematics 6 14 Wiring Diagram Belt Driven Generator 6 13 ...
Page 223: ...Section 6 Schematics December2013 6 15 Wiring Diagram 3kW Hydraulic Generator 6 16 ...
Page 234: ...December2013 Section 6 Schematics 6 26 Hydraulic Schematic 2WD Models after SN 21396 6 25 ...
Page 238: ...December2013 Section 6 Schematics 6 30 Hydraulic Schematic 4WD Models after SN 21396 6 29 ...
Page 365: ...Section 6 Schematics December2013 6 157 Electrical Schematic S 60 HC CE 6 158 ...
Page 368: ...December2013 Section 6 Schematics 6 160 Chassis Wiring Diagram S 60 HC CE 6 159 ...
Page 373: ...Section 6 Schematics December2013 6 165 Platform Control Box Wiring Diagram S 60 HC CE 6 166 ...
Page 461: ......