Part No. 147753
S-60 • S-65 • S-60 TRAX • S-65 TRAX
4 - 15
S-60 HC • S-60X • S-60XC
December 2013
Section 4 • Repair Procedures
PLATFORM COMPONENTS
2 Remove all weight, tools and equipment from
the platform.
Tip-over hazard. Failure to remove
all weight, options, accessories
and/or tools from the platform or
subtracting the weight of those
items from the test weights, will
result in the platform load sense
system not calibrating correctly.
This will allow too much weight to
be added to the platform which will
result in the machine tipping over.
3 Open the ground control box and locate the
calibration toggle switch near the relays.
Note: If either the operational and/or safety
controller has been replaced or if the software has
been updated, restore the system to the default
settings and then continue to step 4. See
How to
Restore the Default Settings.
Otherwise, continue
to step 4 to enter calibration mode.
4 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position.
Result: The alarm sound for approximately
2 seconds.
5 Activate and release the calibration toggle
switch 3 times within 2 seconds after the alarm
sounds to enter calibration mode.
Result: The alarm should sound for 1 second
indicating the first calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking twice indicating that
step 2 of calibration is next.
Result: The alarm did not sound and the green
LED on the operational controller is not blinking
fast. Repeat this procedure beginning with
step 1.
Note: Once calibration mode is entered and begun,
there is a 8 minute time limit between each
calibration step. If any one step passes the 8
minute time limit, the system will time out and the
calibration process will need to be repeated
beginning with step 1.
a
green LED (operational control module)
b
red LED (operational control module)
c
operational control module
d
safety control module
e
red LED (safety control module)
f
green LED (safety control module)
How to Restore the System
Default Settings
1 Turn the key switch to ground control and
pull out the red Emergency Stop button to
the on position.
Result: The alarm should sound a long tone.
2 Activate and hold the calibration toggle
switch for 5 seconds.
Result: The alarm should sound a tone for
1 second.
3 Push in the red Emergency Stop button to
the off position.
f
e
b
a
c
d
Summary of Contents for S-60 HC
Page 1: ......
Page 215: ...Section 6 Schematics December2013 6 7 Ford DSG 423 Engine Wire Harness 6 8 ...
Page 218: ...December2013 Section 6 Schematics 6 10 Ford MSG 425 Engine Wire Harness 6 9 ...
Page 219: ...Section 6 Schematics December2013 6 11 Electrical Schematic Options All Models 6 12 ...
Page 222: ...December2013 Section 6 Schematics 6 14 Wiring Diagram Belt Driven Generator 6 13 ...
Page 223: ...Section 6 Schematics December2013 6 15 Wiring Diagram 3kW Hydraulic Generator 6 16 ...
Page 234: ...December2013 Section 6 Schematics 6 26 Hydraulic Schematic 2WD Models after SN 21396 6 25 ...
Page 238: ...December2013 Section 6 Schematics 6 30 Hydraulic Schematic 4WD Models after SN 21396 6 29 ...
Page 365: ...Section 6 Schematics December2013 6 157 Electrical Schematic S 60 HC CE 6 158 ...
Page 368: ...December2013 Section 6 Schematics 6 160 Chassis Wiring Diagram S 60 HC CE 6 159 ...
Page 373: ...Section 6 Schematics December2013 6 165 Platform Control Box Wiring Diagram S 60 HC CE 6 166 ...
Page 461: ......